Results

The Insides Company

Does the retention sleeve on the Tube get caught on the aperture of the ostomy appliance? Lift the tube into a horizontal position when threading the ostomy appliance on.

The Insides Company

Do you have any suggestions on what ostomy appliances and accessories that work best with the device? (1-minute read). Click here to download. We recommend using the ostomy appliance and accessories that work best for the patient.

The Insides Company

Ostomy appliance. Prepare The Insides® Tube. Unwrap the arms of retention sleeve. Ensure the retention sleeve is positioned towards the base of the tube. Ensure the guidewire sits in the tip of the bulbous feature.

The Insides Company

A high output ostomy appliance will be required to fit the tube and Pump comfortably. It is recommended to use a clear ostomy appliance so the tube can be visualised. The Pump cannot be pressed against the end of the bag.

The Insides Company

Release excess wind in the ostomy appliance. Press out the wind via the opening at end of pouch or uncoupling the pouch from the base plate. Do not let the ostomy appliance overfill. Refeed once you see The Insides® Pump is submerged.

The Insides Company

No, nothing should be added to a patient’s ostomy appliance to reinfuse. Only intestinal content that naturally passes into the patient’s ostomy appliance should be reinfused except for water during the initial testing. Popular Searches. Chyme. Fistula.

The Insides Company

The device works to refeed chyme from an ostomy appliance, into the distal limb of the intestinal tract through the stoma. The housing and adapter are assembled together through the drain port of an ostomy appliance.

The Insides Company

Ostomy appliance. Parenteral nutrition. Intestinal failure. Choose Your Language. Selecting language below will change the language for theinsides.co. English. Français. Dansk. Español. Deutsche. Italiano. Nederlands. Svenska. Polski. Türk. 日本語.

The Insides Company

If the housing is not in place, it will leak through the port of the ostomy appliance. If the adapter is not properly connected to the housing, chyme may leak out through the device.

The Insides Company

Ostomy appliance. Parenteral nutrition. Intestinal failure. Choose Your Language. Selecting language below will change the language for theinsides.co. English. Français. Dansk. Español. Deutsche. Italiano. Nederlands. Svenska. Polski. Türk. 日本語.

Choose Your Language

Selecting language below will change the language for theinsides.co